Definite Purpose Contactor · 40A 2-Pole 24 VAC Coil Open Type - Eaton C25BNB240T
What this product is for
The Eaton C25BNB240T is a compact definite purpose contactor used to switch line voltage loads from a 24 VAC control circuit. It is commonly selected for HVAC condensing units, compressors, fan motors and other equipment where a 2-pole open contactor is required.
Use for
Use for replacing or specifying a 40A 2-pole contactor with a 24 VAC coil in control panels, rooftop units, condensers and similar equipment. Typical applications include motor and resistive load switching where the equipment nameplate and control circuit match this contactor's ratings.
Avoid for
Avoid for applications requiring an enclosed contactor, different coil voltage, different pole configuration, or reversing duty. Do not substitute based only on frame size; confirm ampacity, coil voltage, terminal style and equipment approval requirements.
Best for
Best for service replacements and OEM-style maintenance where a compact 2-pole definite purpose contactor with 24 VAC control is needed. Electricians and HVAC technicians typically look for the coil voltage first, then pole count, then current rating when matching a replacement.
Installed in
Typically installed in HVAC condensing units, air handlers, refrigeration equipment, pump panels and other machinery using a low-voltage control circuit. This is an open style device intended for installation inside suitable equipment enclosures or control compartments.
Why this product exists
This contactor allows a low-voltage 24 VAC control signal to switch higher voltage power circuits safely within the equipment design. In trade use, 24 VAC coils are common in HVAC controls because they integrate with standard thermostats and control transformers.
Compared with similar products
Compared with general purpose contactors, a definite purpose contactor is typically more compact and application-specific for HVAC and equipment control. Compared with a 1-pole contactor, this 2-pole design disconnects both ungrounded conductors in many 240 VAC applications, depending on equipment design. Actual suitability depends on the original equipment specification and local electrical code.
Specifications
- Manufacturer: Eaton
- Manufacturer part number: C25BNB240T
- Product family: C25 definite purpose contactor
- Type: Compact definite purpose contactor
- Current rating: 40 A
- Poles: 2-pole
- Coil voltage: 24 VAC, 50/60 Hz
- Voltage rating: 600 VAC
- Configuration: Open type, non-reversing
- Terminals: Box lug terminals
- Mounting: Metal mounting plate / panel mount style
- Typical application voltage: Often used on 208 to 240 VAC equipment circuits where the control circuit is 24 VAC
Typical buying guidance only: on HVAC equipment, matching the 24 VAC coil and pole configuration is usually as important as matching the amp rating. Actual performance depends on equipment design, load type, enclosure, and local electrical code.
- MountingMetal mounting plate / panel mount style
- Product FamilyC25 definite purpose contactor
- Current Rating40 A
- Poles2-pole
- Coil Voltage24 VAC, 50/60 Hz
- Voltage600 VAC
- ConfigurationOpen type, non-reversing
- TerminalsBox lug terminals
- BrandsEaton
Aptico Supply Delivery
Fast Electrical Supply Delivery Across Ontario
Local delivery routes, pickup options, and contractor-focused service from our Elmira and Flesherton locations.

Delivery Built Around Electrical Contractors
Aptico Supply helps electricians, contractors, and commercial buyers get the electrical materials they need without unnecessary delays. Whether you are ordering for a jobsite, restocking service inventory, or arranging pickup, our delivery options are designed to keep work moving.
Free Daily Delivery
Free daily delivery is available for larger contractor accounts.
- Order by 9:00 AM for morning delivery
- Order by 2:00 PM for afternoon delivery
- Available in qualifying local delivery areas
Free Weekly Delivery
Free weekly delivery is available for smaller accounts in select service areas.
- Elmira area delivery: Tuesday
- Flesherton area delivery: Thursday
- Order by 11:00 AM on the route day
Pickup Options
Pickup is available from our Ontario locations for customers who prefer to collect their order directly.
- Elmira pickup available
- Flesherton pickup available
- Call ahead for large or special-order items
Local Delivery Areas
See our local delivery coverage below. Delivery charges may apply outside regular route areas or for oversized items.
Delivery Questions
Do you offer free delivery?
Yes, free delivery is available for qualifying contractor accounts and selected local delivery routes.
Can I pick up my order?
Yes, pickup is available from our Elmira and Flesherton locations.
Do delivery charges apply?
Delivery charges may apply outside regular local routes, for smaller orders, or for oversized and heavy items.
Can you deliver to jobsites?
Yes, jobsite delivery may be available depending on the order size, location, and delivery schedule.
Need Electrical Supplies Delivered?
Contact Aptico Supply to confirm your delivery options, pickup availability, or contractor account eligibility.
Contact Aptico SupplyWe accept the following payment methods:
To replace this text with your store's actual info on payment methods, go to "Design -> Menus & Pages -> Product Page Tabs" and edit the Payment methods page.
This page is intended for your policy regarding returns and refunds.
Here you can provide information as to what products can be returned, how many days your customers have to return their purchase, whether they will receive a refund in the original form of payment, a replacement or a store credit, who pays for the shipping of the previously purchased products to the store, and so on.
To replace this text with your store's actual return policy, go to "Design -> Menus & Pages -> Product Page Tabs" and edit the Return Policy page.